Dedicated to the simulation of the reliability of environmental testing instruments and mechanics, optical, battery, aging, automotive, electronic precision instruments and equipment research and development, production, sales and service of professional manufacturers
Dongguan Xinhang Instrument Equipment Co., Ltd

One stop laboratory testing instrument and equipment supplier

National Service Hotline

13925864159
13144873913

Scan it

Follow Xinhang Yi Qi

Quickly obtain discounted quotes

Products
Products
Products

Consultation hotline

13925864159
13144873913

Split type coating thickness gauge
  • Split type coating thickness gauge
  • Split type coating thickness gauge
Split type coating thickness gauge

型号:XH-TC-271

  • Product details
  • Requesting samples and information

summary

The eddy current measurement method can be used to non-destructive detect the thickness of non-conductive insulation coatings on non-magnetic metal substrates (such as rubber, plastic, paint, oxide film, etc. on aluminum, copper, zinc, tin, etc.).

This instrument can be applied in testing fields such as electroplating, anti-corrosion, chemical, automotive, shipbuilding, light industry, and commercial inspection. It can be used in both laboratories and engineering sites. It is an important instrument in the testing industry.


major function

There are two measurement methods: continuous measurement and single measurement;

There are two working modes: direct and group mode;

● Equipped with automatic statistical functions: mean (MEAN), maximum (MAX), minimum (MIN), number of tests (NO.), standard deviation (S.DEV);

Two methods, single point calibration and two-point calibration, can be used to calibrate the instrument, and the basic calibration method can be used to correct the systematic error of the measuring head;

Storage function: can store 4 calibration workpieces that can be saved. 26 groups in each category, 15 in each group, with a total of 1560 measurements;

● Delete function: Delete individual suspicious data that appears in the measurement, or delete data in the storage area for new measurements;

● Setting limits: Automatic alarm for measured values outside the limit;

Equipped with power undervoltage indication function, with a buzzing sound during operation and automatic shutdown mode.


technical parameter

project

XH-TC-271

Probe type

N1

operational principle

Eddy current

measuring range

0-1250μM

Low resolution limit

0.1μM

Indication error

One point calibration

±(3% H 1)

Two point calibration

±[(1-3%) H 1]

Test conditions

Minimum curvature radiusMm

Convex1.5mmConcave9mm

Minimum area diameterMm

Φ7mm

Basic critical thicknessMm

0.5mm

work environment

temperature

0-40℃

humidity

20%~90%

source

1.5VTwo sections

External dimensions

163X78X33mm(Host)

weight

200g

Shell material

Plastic shell

Standard configuration

Host, standard test piece, iron substrate, alkaline battery, instrument box, probe

Optional configuration

Standard test piece, substrate, sheath, probe

Compliant with standards

1. GB/T 4956-2003 Measurement of non-magnetic coating thickness on magnetic metal substrates Magnetic methods

2. GB/T 4957-2003 Eddy current method for measuring the thickness of non-conductive coatings on non-magnetic metal substrates

3. JB/T 8393-1996 Magnetic and Eddy Current Coating Thickness Measuring Instruments

4. JJG 889-95 "Magnetic reluctance thickness gauge"

5. JJG 818-93 Eddy Current Thickness Gauge


measuring principle

This instrument adopts the principle of eddy current measurement and can measure the thickness of non-conductive coatings (such as enamel, rubber, paint, plastic, etc.) on non-magnetic metal substrates (such as copper, aluminum, zinc, tin, etc.).

A. Eddy current method (N-type probe): Using high-frequency alternating current to generate an electromagnetic field in the coil, when the probe contacts the covering layer, eddy currents are generated on the metal substrate, and feedback is generated on the coil in the probe. The thickness of the covering layer can be derived by measuring the magnitude of the feedback effect.

                      image.png             

Measurement steps

A) Place the probe in an open space, press the power button to turn it on, and check the battery voltage

explain

1: When the battery symbol is displayed at full capacity, it indicates that the battery voltage is normal; When the battery level is less than 2 cells, please replace the battery immediately to ensure measurement accuracy.

2: When not in use for a long time, the battery should be removed. When booting up, the display interface is as follows:

"NFe" - N-type probe, tested on a non-ferrous substrate

"A" - Measurement mode

"Value" - measured value

B) Choose appropriate calibration methods for standard instruments.

C) Measurement method: Hold the sliding sleeve and make vertical contact between the measuring head and the testing surface. With a beep, the screen displays the measurement value. Lift the side head to proceed with the next measurement

D) Shutdown: Press the power button, or the instrument will automatically shut down after about 5 minutes.

Explanation:

If the measuring head does not make vertical contact with the surface to be measured during measurement, a measurement value with a large error may be displayed. You can press the clear button to clear this value;

After measuring three or more times, the instrument can automatically perform statistical analysis on the measurement data, including average value, deviation, number of measurements, maximum measurement value, and minimum measurement value.


Maintenance and repair

1. Environmental requirements

Strictly avoid collisions, heavy dust, humidity, strong magnetic fields, oil stains, etc.

2. Replacing the battery

When the battery level on the screen is displayed as less than 2 bars when turned on, it indicates that the battery should be replaced.

3. Instrument maintenance

When a malfunction occurs, please do not disassemble the machine for self repair. After filling out the warranty card, please hand over the instrument to our company's maintenance department to comply with the warranty regulations. If you could briefly describe the situation where the error occurred and send it out together, we would greatly appreciate it.

Get a free quote now!

Fill out the form below, including as much detailed information as possible, and we will reply to you as soon as possible.

address

No. 8, Henggang Ma Yuan 1 Heng Lane, Fenghuang Gang, Tangxia Town, Dongguan City, Guangdong Province, China

contacts

13925864159
13144873913

We are a professional manufacturer dedicated to the research and development, production, sales, and service of simulation reliability environment testing instruments, as well as mechanical, optical, battery, aging, automotive, and electronic precision instruments and equipment.
Copyright © 2024 Dongguan Xinhang Instrument Equipment Co., Ltd