Product features
High, low temperature, and low pressure test chambers are used in defense industry, aerospace industry automation components, automotive components, electronic and electrical components, plastics, chemical industry, food industry, pharmaceutical industry, and related products to simulate high-altitude, high-altitude, and (high-altitude) climate for storage, transportation, and reliability testing under single or simultaneous effects of high, low temperature, and low pressure. Electrical performance parameters of the test specimens can also be tested when powered on at the same time.
Features:
1. Internal pressure structure of the main box structure;
2. Temperature and humidity control system: fan, heater, evaporator;
3. Refrigeration method: mechanical compression binary refrigeration system;
4. Vacuum unit: rotary vane vacuum pump;
5. Control panel: Temperature, humidity, and pressure control display screen, over temperature. Protective device, light switch.
Standard:
GB/T2423.1-2001 Test A: Low temperature test GB/T2423.2-2001 Test B: High temperature test
GB/T t2423.21-2001 Test M: Low pressure test
technical specifications
model
|
High, Low Temperature, and Low Pressure Test Chamber XH-GDS Volume AB
|
Internal volume (L)
|
225L
|
408L
|
1000L
|
1700L
|
3300L
|
Studio size (WxDxH) (mm), width, depth, and height
|
600x500x750
|
800x600x850
|
1000x1000x1000
|
1200x1200x1200
|
1500x1500x1500
|
|
temperature range
|
A: -40 ℃~150 ℃ B: -20 ℃~150 ℃ C: -60 ℃~150 ℃ D: -70 ℃~150 ℃ Please choose the standard: A -40 ℃~150 ℃
|
Pressure range
|
Atmospheric pressure~1KPa/Atmospheric pressure~0.5KPa
|
Pressure accuracy
|
± 2KPa (at atmospheric pressure~40KPa); ± 5% (at 40KPa to 4KPa); ± 0.1KPa (4KPa~1KPa)
|
Pressure reduction rate/pressure recovery
|
≤ 50min (atmospheric pressure → 1KPa); ≤ 10kpa/min
|
Humidity range
|
20%~98% R H (10%~98% R.H, 5%~98% R.H; customized for special conditions)
|
Temperature distribution uniformity
|
≤ ± 2 ℃
|
Temperature/humidity control fluctuation
|
± 0.5 ℃ atmospheric pressure/≤ ± 2.5% R.H
|
Temperature/humidity deviation
|
≤ ± 2 ℃/75% R H<± 5% R H, 75% R H ≥ ± 3% R H,
|
heating rate
|
About 2 ℃/minute; Normal pressure no-load (temperature rate of 2-25 ℃/minute, linear/nonlinear, special conditions need to be customized)
|
cooling rate
|
Approximately 0.7-1.7 ℃/minute; Normal pressure no-load (temperature rate of 2-25 ℃/minute, linear/nonlinear, special conditions need to be customized)
|
Inner/outer shell material
|
SUS304 mirror stainless steel/anti rust treated cold-rolled steel plate spray coating/SUS304 brushed stainless steel
|
Refrigeration method
|
Fully enclosed dual stage compressor (air-cooled)/German BITZER compressor or German GEA blog compressor (water-cooled)
|
Environmental temperature/humidity
|
Air cooling 5 ℃~26 ℃, water cooling 5 ℃~35 ℃/≤ 85% RH
|
source
|
380V ± 10% 50HZ
|