Flexible control: The system can perform automatic cycle lifting or manual selective impact, and can set three zone impact and start of cold and hot impact
Fast conversion: High and low temperature conversion time: within 10 seconds (other requirements to be agreed upon)
Fast cooling: The cooling adopts a binary freezing system, which has a fast cooling effect. The cooling method is water-cooled
Long term impact: When subjected to high or low temperature impact, the maximum time can reach 999H and the maximum cycle time can reach 9999 times
Food National Army Standards: Implementation of Standards and Test Methods: GJB150.5, GJB360.7, GB/2423.22
Product features
※ Adopting fully automatic PID control with high precision and can save 30% electricity,
The two boxes of equipment are divided into two parts: high temperature zone and low temperature zone. The test product is placed in a basket, and during impact, the basket moves the test product into the high temperature zone or low temperature zone for balancing. The test product is dynamic and equipped with a door opening safety system.
※ Adopting a touch based graphic control interface, the operating cylinder is easy to operate.
※ The impact method applies the wind path switching method to import the temperature into the testing area for cold and hot impact testing.
When subjected to high or low temperature shock, the maximum time can reach 999H and the maximum cycle cycle can reach 9999 times.
The system can be used for automatic cycling or manual selective shock, and can be set to start the secondary cold and hot shock.
※ The cooling adopts a binary freezing system, which has a fast cooling effect.
※ Hanging basket conversion time: within 10 seconds (other requirements to be agreed upon)
※ Implement the standard and test method: GJB150.5 temperature shock test; GJB360.7 temperature shock test; GB/2423.22
technical specifications
model
|
XH-LRS2-512L
|
Internal dimensions WxDxH (cm)
|
eighty × eighty × 80 (or non-standard customization is possible)
|
Basket temperature range ℃
|
150 ℃~ABC
|
A-40
|
B-55
|
C-65
|
Preheating temperature ℃
|
60 ℃~200 ℃
|
Pre cooling temperature ℃
|
A: -10 ℃~-55 ℃ B: -10 ℃~-70 ℃ C: -10 ℃~-75 ℃
|
High temperature impact range
|
60 ℃~160 ℃
|
Low temperature impact range
|
A: -10 ℃~-40 ℃ B: -10 ℃~-55 ℃ C: -10 ℃~-65 ℃
|
Heating time (thermal storage zone) min
|
RT~200 ℃ requires approximately ≤ 35 minutes
|
Cooling time (cold storage area) min
|
A: 20~-55 ℃ takes about 60 minutes B: 20~-70 ℃ takes about ≤ 70 minutes C: 20~-75 ℃ takes about 85 minutes
|
Hanging basket conversion time
|
10S
|
Operating ambient temperature
|
Water cooling environment temperature requirement: 5~35 ℃
|
Temperature recovery time
|
Within 5 minutes
|
High temperature exposure for 30 minutes
|
Low temperature exposure for 30 minutes
|
Temperature control accuracy
|
± 0.5 ℃
|
Uniformity
|
± 2.0 ℃
|
Internal and external materials
|
Steel plate electrostatic spraying surface treatment or SUS 304 stainless steel
|
Internal material
|
SUS 304 stainless steel
|
Insulation material
|
High density polyurethane foam glass wool
|
control system
|
7-inch touch screen, displayed in both Chinese and English, with 120 programs, 1200 segments, 99 full cycles, 99 partial cycles, temperature of 0.1% of F.S ± 1 digit, humidity of 0.1% of F.S ± 1 digit, temperature of pt-100, humidity of pt-100 or 5V DCV communication USB or RS485 (other communication negotiation)
|
Refrigerant
|
R404/R23 (environmentally friendly refrigerant)
|
Cooling system
|
Semi enclosed double stage compressor (water-cooled)
|
Safety protection devices
|
1. Compressor overpressure, overheating, and overcurrent protection; 2. High pressure protection switch for refrigerant; 3. Fault alarm system; 4. Heat storage high temperature and cold storage low temperature protection; 5. Electronic alarm;
6. Water shortage alarm protection (water cooling); 7. No fuse switch; 8. Power phase sequence protection; 9. Temperature protection of test chamber
|
Standard accessories
|
Two sample racks, measuring wire hole diameter 50mm * 1, power cord, instruction manual
|
source
|
AC380V 50HZ three-phase four wire ground wire
|
controller
|
Korea TECH Three Yuan/Taiwan Tong TATO
|
compressor
|
BITZER compressor from France/GEA blog compressor from Germany
|